The products are dispatched from the warehouse in Germany.

Renogy Pre-Sale Phone Support(English) Mon-Fri 9AM to 6PM +44 3300589559 Contact Us

RENOGY Battery Shunt 300

SKU: RSHST-B02P300-EU
€125,99 €142,99
Tax included. Shipping by weight.
+ 1250   Renogy Rays after purchase.
Log In Learn More

  • Remote monitoring and control via Renogy ONE and DC Home App.
  • Compatible with various batteries: Lead-Acid, LFP, Li-ion, and Ni-MH.
  • Displays State of Charge, temperature, and starter battery voltage.
  • Records historical data and issues alerts via DC Home App.
Quantity:
Enjoy payments with
Return & refund policy

What is Renogy's Return Policy?

Return within 30 Days

You may return your product(s) to Renogy within 30 days of delivery. The item(s) must be in the original packaging, be unused, undamaged, and unmodified. A refund will be issued after the returned item is inspected by Renogy.

Start a Member ReturnStart a Guest Return

Renogy will pay for the return shipping label for items that fall within the following categories:

  • Carrier damage/ warehouse mishandling
  • Defective product
  • Incorrect product was delivered
  • Additional product(s) you did not order were delivered

For any other reason not listed, customers are responsible for any return shipping fees. Renogy will NOT accept returns with any modifications to the product as it voids our warranty. Any modified products returned to Renogy will be shipped back to you at your own expense.

Return after 30 Days

Return requests outside of 30 days require special authorization. You can submit a case through our online portal to request a late return.

Submit a Case

FAQs

Can I exchange my Renogy order?

Renogy does not offer exchanges. If you purchase the wrong item by mistake, you will need return the item and place a separate order for the correct one. The return shipping expenses shall be borne by you.

Where is my refund?

Once we have confirmed that the return requirements are met, we will issue a full refund within 2-5 business days. Actual deposit times may vary according to your banking institution. Additionally, an email notification will be sent out when the refund is issued.

What about defective or faulty items?

We stand behind all of our products. If the item(s) you received is defective or flawed in any way, please submit a case  on our online portal and describe the issue you are encountering.

----

Click here to view the full content of Return & Refund Policy.

Description
Includes
Specs
Downloads
FAQ
Reviews

Check Your Battery Charging Level Anytime, Anywhere

Ensures precise battery monitoring via the Renogy ONE Core and DC Home App.

Data Analysis
Batteries Compatibility
Trusted Performance
Temperature Sensor

Track Battery Performance Over Time

In addition to real-time data monitoring, the Battery Shunt 300 also helps to record historical data via Renogy ONE Core and DC Home App, allowing you to make informed decisions about your entire power system.

Compatible With All Types of Batteries

The Shunt 300 is compatible with all your starter and main batteries, including lead-acid (AGM, GEL), lithium iron phosphate (LiFePO4), lithium-ion, and nickel-metal hydride (NiMH).

Certified Performance

The Shunt 300 has undergone comprehensive testing to surpass exceptionally high standards of excellence.

Battery Temperature Sensor

Temperature sensors for batteries are essential for ensuring safety, longevity, efficiency, and enabling data-driven decision-making in various applications.

5-Minute Installation
Fast Connection
Quick Setup

Effortless Installation in 5 Minutes

It can be placed on top of the battery or securely mounted on the wall with screws. The connection points are equipped with protective covers to prevent loosening caused by movement.

Fast Connection in 4 Steps

When paired with Renogy ONE Core and DC Home, the Shunt 300 provides a seamless real-time data display and monitoring experience.

Quick Setup Involves Simple Operations to Get Started

The initial steps are designed to be user-friendly and straightforward, allowing users to get started quickly.

Package Includes

Battery Shunt 300

x 1

Quick Guide

x 1

Mounting Screws

x 3

B+ Wires (1 m) (22 AWG)

x 2

Temperature Sensor (1.5 m)

x 1

Battery Shunt 300

ELECTRICAL DATA

Model Name
RSHST-B02P300-G1
Voltage Input Range
8V to 120V DC
Power Consumption
<0.1 W
Communication
Bluetooth LE and BLE Mesh
Max continuous current
300A
Max peak current
500A(<10s)
Current accuracy
±1%
Current Resolution
0.01 A
Battery Capacity
1 - 6500Ah
Voltage Input Range
8 - 60V
Voltage input resolution
10 mV
Temperature sensor range
-20~80℃
Temperature sensor accuracy
±1%
Operating Temperature
-10°C to 50°C
Operating Humidity
0% to 95% RH
Operating Altitude
Less than 2000m above sea level
Installation
Surface mounting
Battery connection
M10 bolts
Weight
0.57lb (260g )
Dimensions
5.27 x 3.82 x 1.22 inch (134 x 97 x 31 mm)
Warranty
1 year
Certifications
CE, FCC ID,IC ID,RCM,TSCA, RoHS,UN38.3,TELEC

Frequently Asked Questions

1.In DC Home or Renogy ONE, the current is shown as negative when charging and positive when discharging.

Inspect for reverse contact on B- or Pterminals.

2. Incorrect temperature reading

Confirm the Battery Temperature Sensor is properly installed.

3. Incorrect SOC reading

The battery capacity decreases as the charging and discharging cycles increase.Re-configure the “Rated Battery Ah” to the capacity when the battery is fully charged.

4.Inaccurate sampling precision in large-current scenarios

Elevated ambient temperatures can affect sampling accuracy. Ensure proper ventilation for the shunt and remove the upper cover if needed.

5.What should I do if my Battery Shunt 300 is showing only discharging readings?

If you notice that your Battery Shunt 300 displays only discharging readings after installation, with the readings staying at zero, please follow these steps: 1.Remove Battery Shunt from both Renogy One Core and DC Home. 2. Uninstall the DC Home app and install a new DC Home app. 3. To avoid potential conflicts, turn off your phone before proceeding. 4.Set Renogy One Core to pairing mode and reset the Battery Shunt. 5.Pair Renogy One Core and Battery Shunt 300, then turn on your phone. 6.Activate pairing in DC Home; you will see a link, not the Battery Shunt 300 readings. However, this link is pairing Battery Shunt 300 and Renogy One Core with DC Home. 7. Pair this link. By following these steps,you can resolve the issue, and the Battery Shunt 300 readings displayed correctly. If the issue persists, it's recommended to contact Renogy's technical support for further assistance.

6.Why does the SOC alarm parameter on my Battery Shunt reset to 50% in Renogy Core One settings?

If you're experiencing an issue where the State of Charge (SOC) alarm parameter you set for the Battery Shunt in Renogy Core One settings resets to 50% after a short period, follow these steps for troubleshooting: 1.Turn off the power to the Battery Shunt 300. 2.Delete the Battery Shunt 300 from the Renogy One Core settings. 3.Turn the power back on for the Battery Shunt 300. 4.Add the Battery Shunt 300 back to the Renogy One Core. 5.Refer to the user manual for the Battery Shunt 300 and follow the provided instructions for setting up the SOC alarm parameter. By following these troubleshooting steps, you can resolve the issue of the SOC alarm parameter resetting to the default value.If the issue persists, it's recommended to contact Renogy's technical support for further assistance.

7.What should I do if my Battery Shunt 300 can connect to my phone but not to Renogy One Core?

If your Battery Shunt successfully connects to your phone but faces issues connecting to Renogy One Core, consider the following steps: 1.Check Renogy One Core Firmware 2.Reset the Battery Shunt 300:Press and hold the reset button on the Battery Shunt for 5 seconds until the Bluetooth light turns off. 3.Connection Steps:On the Renogy One Core, click "Add Device" and scan for the Battery Shunt 300.Once detected, the Battery Shunt's Bluetooth light should stay solid. By following these troubleshooting steps, you can resolve issues related to Battery Shunt connectivity with the Renogy One Core. If problems persist, contact Renogy's technical support for further assistance.

8.Battery charge percentage doesn’t show and the Consumed Ah reading is way off.

If you encounter abnormal data readings on the Battery Shunt 300, follow these troubleshooting steps: 1.Power off the Battery Shunt 300 and restart it. 2.Perform charge and discharge cycles on the battery pack connected to the Battery Shunt 300. 3.After the restart and cycling, check if the consumed Ampere-Hours (AH) reading returns to normal. If the issue persists after the above steps, please contact our support team for further assistance.

9.The Battery Shunt 300 doesn't have programming options for lithium or lead-acid batteries. Can it not be programmed for lithium or lead-acid batteries?

Battery Shunt 300 does not differentiate between battery types. Its calculations are based on current and voltage. During the initial connection, it will prompt you to input the battery capacity. It can also be manually calibrated. After fully charging the battery, set the current SOC to 100% in the settings.While specific programming for different battery types isn't available, these settings and manual adjustments ensure precise monitoring and control.

10.Can the Battery Shunt 300 handle battery banks larger than 300A?

The 300A specification of the Battery Shunt represents its maximum capacity rather than indicating a limitation based on battery bank size. It is not restricted to use only with 300A battery banks. To ensure compatibility, calculate the actual maximum continuous current in your circuit, and the Battery Shunt 300 should be suitable for monitoring larger battery banks.

Reviews